2805 Bowers Ave, Santa Clara, CA 95051 | 408-730-2275
sales@colfax-intl.com
My Colfax  

Colfax CX1260s-S12-X7 1U Rackmount Server

 
 
  • 2x Intel® Xeon® Scalable Processors
  • 12x DIMMs
  • 12x 3.5" SAS3/SATA3 Drive Bays
  • 4x 2.5" NVMe/SATA Drive Bays

Features

  • 2x Intel® Xeon® Scalable Processors
  • Intel C622 Chipset
  • 12x DIMMS, Supports DDR4 ECC RDIMMM/LRDIMM
  • Expansion Slots:
    - 3 PCI-E 3.0 x16 Slots
    - 1 PCI-E 3.0 x4 NVMe M.2 Slot
    - Add-on-Module Slot (AOM Broadcom 3216 SAS3 IT Mode)
  • 12x 3.5" Hot-Swap SAS3/SATA3 Drive Bays
  • 4x 2.5" 7mm Hot-Swap NVMe/SATA Drive Bays
  • 2x 10GBase-T Ports via Intel C622
  • 800W Redundant Power Supply, 80PLUS Platinum
  • Integrated IPMI 2.0 with KVM and Dedicated LAN




Intel, the Intel logo, Xeon, and Xeon Inside are trademarks or registered trademarks of Intel Corporation in the U.S. and other countries.

Technical Specifications

CPU • Dual Socket P (LGA 3647)
• Supports Intel® Xeon® Scalable processor (TDP 205W*)

* 205W CPU support up to 32°C. 75W-165W CPU support from 10°C ~ 35°C.
Memory • 12x DIMM Sockets
• Supports up to 3TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM
• Memory Type 2933/2666/2400/2133MHz ECC DDR4 SDRAM
Chipset • Intel® C622
I/O Expansion • 3 PCI-E 3.0 x16 slots
• 1 PCI-E 3.0 x4 NVMe M.2 slot
• AOM slot (AOM Broadcom 3216 SAS3 IT Mode)
Onboard Devices SATA
• SATA3 (6Gbps); RAID 0, 1, 5, 10
Network Controllers
• Dual LAN with 10GBase-T from Intel C622
IPMI
• Support for Intelligent Platform Management Interface v.2.0
• IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
VGA
• ASPEED AST2500 BMC
Input / Output LAN
• 2x RJ45 10GBase-T LAN ports
• 1x RJ45 Dedicated IPMI LAN port
USB
• 4x USB 3.0 ports (rear)
• 2 USB 2.0 ports (front)
VGA
• 1x VGA port
TPM
• 1 TPM Header
Chassis Form Factor • 1U Rackmount
• Dimension (WXHXD): 17.6" (447mm) x 1.7" (43mm) x 37.40" (950mm)
Power Supply • 800W Redundant Power Supplies with PMBus
• Input
- 750W: 100-127Vac / 10A
- 800W: 200-240Vac / 5.5A
- 800W: 230-240Vdc / 5.5A
• +12V
- Max: 62.5A /Min: 0.5A (100-127Vac)
- Max: 66.6A /Min: 0.5A (200-240Vac, 230-240Vdc)
• +5V sb
- Max: 4A /Min: 0A
• 80PLUS Platinum Certified
Storage • 12x hot-swap 3.5" SAS3/SATA3 drive bays
• 4x hot-swap 2.5" 7mm NVMe/SATA drive bays
System Cooling • 6x 40x40x56mm 20.5K-17.6K RPM counter-rotating fans
Front Panel Buttons
• Power On/Off button
• System Reset button
LEDs
• Power status LED
• Hard drive activity LED
• Network activity LEDs
BIOS • UEFI 256Mb


Block Diagram


Images


$2,880.00
 

  Qty.Colfax CX1260s-S12-X7 1U Rackmount Server, Cost As Configured $2,880.00
Base Platform 1
Primary CPU    1

Set next    items (  ) like this
Secondary CPU    1
CPU 1 - Socket 1 of 6    1

Set next    items (  ) like this
CPU 1 - Socket 2 of 6    1
CPU 1 - Socket 3 of 6    1
CPU 1 - Socket 4 of 6    1
CPU 1 - Socket 5 of 6    1
CPU 1 - Socket 6 of 6    1
CPU 2 - Socket 1 of 6    1

Set next    items (  ) like this
CPU 2 - Socket 2 of 6    1
CPU 2 - Socket 3 of 6    1
CPU 2 - Socket 4 of 6    1
CPU 2 - Socket 5 of 6    1
CPU 2 - Socket 6 of 6    1
M.2 NVMe Drive 1
NVME Drive 1    1

Set next    items (  ) like this
NVME Drive 2    1
NVME Drive 3    1
NVME Drive 4    1
Disk Drive 1    1

Set next    items (  ) like this
Disk Drive 2    1
Disk Drive 3    1
Disk Drive 4    1
Disk Drive 5    1
Disk Drive 6    1
Disk Drive 7    1
Disk Drive 8    1
Disk Drive 9    1
Disk Drive 10    1
Disk Drive 11    1
Disk Drive 12    1
Ethernet HBA 1
Infiniband HBA 1
Operating System SW 1
   Colfax CX1260s-S12-X7 1U Rackmount Server, Cost As Configured $2,880.00