2805 Bowers Ave, Santa Clara, CA 95051 | 408-730-2275
sales@colfax-intl.com
My Colfax  

Colfax CX21460g-E8 2U Rackmount Server

 
 

  • Short Depth
  • Hot-Swappable 4-Nodes in 2U
  • 2 Models - Rear Access Nodes and Front Access Nodes
  • Total 4x AMD EPYC™ 7002 Processors
  • Total 32x DIMMS
  • Total 4x 2.5" NVMe Drive Bays
  • Total 8x M.2 NVMe SSDs

Models

  • Rear Access Nodes
  • Front Access Nodes

Features

  • Short Depth
  • 4x AMD EPYC™ 7002 Series Processors (1/Node)
  • 32x DIMM Sockets Supporting ECC DDR4 RDIMM and LRDIMM (8/node)
  • 8x PCIe 4.0 x16 Low-Profile Slots (2/node)
  • 4x OCP 2.0 3.0 x16 Mezzanine Slots (1/node)
  • 4x 2.5" Hot-Swap NVMe Drive Bays (1/node)
  • 8x M.2 with PCIe 3.0 x4 Interface (2/node)
  • 8x 1Gb/s Intel® I350-AM2 LAN Ports (2/node)
  • 4x Dedicated Management Ports (1/node)
  • 1x CMC / Ring Topology Module (Optional)
  • 2x 1200 Watts RPSU, 80 PLUS Platinum



Optional CMC / Ring Topology Module

The server supports an optional CMC / Ring Topology Module, featuring an Aspeed CMC (Central Management Controller), LAN hub and dual MLAN ports for multi-node management (including iKVM support) by connecting internally to Aspeed BMCs integrated on each node. This results only in one MLAN connection required to perform management of all four nodes, resulting in less ToR (Top of Rack) cabling and switch connections.

In addition, the LAN hub and dual MLAN ports support the ability to create a "ring" connection for management of all servers in the rack - only two ToR (Top of Rack) switch connections are needed to create the ring system, and the ring will not be broken even if one server in the chain is shut down, reducing cabling and switch port usage for greater cost savings and management efficiency.





GIGABYTE Server Management (GSM)

GIGABYTE Server Management (GSM) is GIGABYTE’s proprietary multiple server remote management software platform, available as a free download. GSM is compatible with either IPMI or Redfish (RESTful API) connection interfaces, and comprises the following sub-programs:

  • GSM Server - a software program with an easy to use browser-based GUI to enable global remote monitoring and management of multiple GIGABYTE servers via each server node’s BMC.
  • GSM CLI - a command-line interface program to enable global remote monitoring and management of multiple GIGABYTE servers via each server node’s BMC.
  • GSM Agent* - a software program installed locally on each GIGABYTE server node that retrieves additional node information (CPU/Mem/HDD/PCI/…) from the OS and passes it to the BMC. This information can then be utilized by GSM Server or GSM CLI.
  • GSM Mobile - a remote server management mobile APP, available for both Android and iOS.
  • GSM Plugin - a plugin that allows the user to manage and monitor GIGABYTE server nodes within VMware’s vCenter.

* GSM Agent is currently compatible with Avocent MergePoint IPMI 2.0 BMC firmware, but not yet compatible with Megarac SP-X BMC firmware.





Intuitive & Informative User Interface

Starting from the GSM Server dashboard, the user can clearly understand the status of each node in the IT environment, including:

  • Node connection status (system is online/offline)
  • Node hardware sensor status (to detect hardware anomalies). Sensors measure voltage, fan speed and temperature
  • Node usage rate status (allowing you to timely allocate more resources when they are needed), including:
    • Power consumption
    • Disk/RAID usage information
    • Memory usage rate
    • CPU usage rate
    • Network card / PCI information

The user can also perform various management functions, including:

  • Node remote access
    • Power on / off / reset
    • Launch iKVM
    • Reboot BMC / BMC Account Configuration
  • Network Configuration
    • IPv4/IPv6 setting
  • Alert Management
    • SNMP trap setting
    • Platform events filters
    • Forwarding alerts by email
  • BMC / BIOS / CPLD Update
  • Power Consumption Limit Setting
  • Group Management
    • Create groups of nodes for BMC / BIOS update or manage power consumption settings


GSM Mobile for iOS and Android

A GSM Mobile app is available for download for both iOS and Android mobile phones for remote server management on the go.


Management through VMware vCenter

A GSM Plugin is available for VMware’s vCenter, allowing the user to perform remote monitoring and management of server nodes without having to switch to a separate software platform.


GIGABYTE Management Console (AMI MegaRAC SP-X)

The server utilizes a AMI MegaRAC SP-X platform for BMC server management, with a feature rich and easy to use browser-based graphical user interface. Notable features include:

  • RESTful API support (including the latest DMTF standards of Redfish) allows the administrator to integrate with 3rd party applications for server management
  • HTML5-based iKVM remote management client included as a standard feature, no additional add-on license required to purchase
  • Detailed FRU information from SMBIOS
  • Pre-event automatic video recording feature from 10 to 30 seconds
  • SAS/RAID controller monitoring feature

Technical Specifications

Enclosure • 2U 4 Nodes
• Dimension (W x H x D) 17.32" x 3.4" x 18.7" (440 x 87.5 x 475 mm)
Short Depth
CPU / Node • Socket SP3
• 1x AMD EPYC™ 7002 series processor
• TDP up to 225W, cTDP up to 240W

NOTE: CPU TDP is limited to 155W if using M.2 device
Memory / Node • 8 DIMM sockets
• 8-Channel memory architecture
• Supports up to 128GB RDIMM/LRDIMM modules
• Memory speed: Up to 3200 MHz
Expansion Slots / Node • 1x Low profile half-length slot with PCIe x16 (Gen4 x16 bus)
• 1x Low profile half-length slot with PCIe x16 (Gen3 x16 bus)
• 1x OCP 2.0 mezzanine slot with PCIe Gen3 x16 bandwidth from CPU_0 (Type1, P1, P2, P3, P4 with NCSI supported)
M.2
• 2 x M.2 slots
- M-key
- PCIe Gen3 x4
- Supports NGFF-2242/2260/2280/22110 cards

NOTE: CPU TDP is limited to 155W if using M.2 device
Storage / Node • 1x 2.5" NVMe hot-swappable SSD bay
Networking / Node • 2x 1GbE LAN ports (1 x Intel® I350-AM2)
• 1x 10/100/1000 management LAN
Video / Node • Integrated ASPEED AST2500 controller
• Connector type - D-Sub 15-pin
• Resolution - up to 1920x1200@60Hz 32bpp
Power Supply • 2 x 1200W redundant PSUs
• AC Input:
- 100-240V~/ 12-7A, 50-60Hz
• DC Input:
- 240Vdc/ 6A
• DC Output:
- Max 1000W/ 100-240V~
+12V/ 80.5A
+12Vsb/ 3A
- Max 1200W/ 200-240V~ or 240Vdc input
+12V/ 97A
+12Vsb/ 3A
• 80 plus Platinum
System Cooling • 3‎ x 80x80x38 mm fans (16,300rpm)
• 1 x 40x40x28 mm fans (25,000rpm)
Internal I/O / Node • 2x M.2 slots
• 1x USB 3.0 header
• 1x TPM header
• 1x OCP 2.0 mezzanine slot
• 1x Front panel header
• 1x Back plane board header
• 1x IPMB connector
• 1x Clear CMOS jumper
• 1x BIOS recovery jumper
Front I/O / Node • 1x Power button with LED
• 1x ID button with LED
• 1x System status LED
• 1x Reset button
Rear I/O • 2x USB 3.0
• 1x VGA
• 2x RJ45
• 1x MLAN
• 1x ID LED
TPM • 1x TPM header with SPI interface
• Optional TPM2.0 kit
Server Management • Onboard Chipset - Aspeed AST2500
• GIGABYTE Management Console (AMI MegaRAC SP-X) web interface
- Dashboard
- JAVA Based Serial Over LAN
- HTML5 KVM
- Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.)
- Sensor Reading History Data
- FRU Information
- SEL Log in Linear Storage / Circular Storage Policy
- Hardware Inventory
- Fan Profile
- System Firewall
- Power Consumption
- Power Control
- LDAP / AD / RADIUS Support
- Backup & Restore Configuration
- Remote BIOS/BMC/CPLD Update
- Event Log Filter
- User Management
- Media Redirection Settings
- PAM Order Settings
- SSL Settings
- SMTP Settings


Block Diagram


Images

Rear Access Model

Front Access Model

Customize the Chassis below or -->
To review or customize any node in this solution, please select the node from the drop-down list

  

$5,769.85
 

  Qty.Colfax CX21460g-E8 2U Rackmount Server, Cost As Configured $4,369.85
Base Platform 1
   Colfax CX21460g-E8 2U Rackmount Server, Cost As Configured $4,369.85