2805 Bowers Ave, Santa Clara, CA 95051 | 408-730-2275
sales@colfax-intl.com
My Colfax  

Viking Enterprise Solutions VDS41022 JBOD

 
 

Enterprise Class High Density 102 Drives High Availability JBOD
VDS41022 JBOD enclosure is a high-density SAS-4 data storage solution that packages 102, 3.5-inch HDDs running at 12 Gb/s SAS with two active 24 Gb/s I/O modules.

Inquire for Pricing

Download Product Brief


Highlights

  • Dual 24Gb/s SAS-4 I/O modules for failover keep the system fully operational even with a single IO module
  • Multiple drive partitioning/split-bus zoning modes
  • Hot-pluggable I/O controllers, fan modules & redundant, high efficiency, advanced power modules & 5V regulators
  • SFF-8644, 24 Gb/s SAS-4 expansion ports
  • Modular design increases product configuration flexibility
  • SAS point-to-point connectivity isolates drive failures, increasing reliability & fault tolerance, while improving performance
  • SAS daisy-chain expansion to additional storage arrays & other SFF-8644 SAS compliant host/expansion ports
  • Single SAS 4.0 I/O module configuration is available, featuring four 4-wide, 24 Gb/s mini SAS HD ports and support for 12 Gb/s-6 Gb/s SAS and 6 Gb/s SATA drives



Technical Specifications

Physical Dimensions 4U Rackmount Enclosure
• Dimensions: 6.9" H X 17.2" W X 39.4" D (17.2 cm H X 43.8 cm W X 100.0 cm D)
• Weight with drives: 275.0 lbs (124.7 kg) max
• Standard rackmount rail kit with optional cable management system
Capacity • 102-drive capacity per 4U enclosure
- 102 drive slots compatible with LFF or SFF drives
- 12Gb/s supported on all drive slots
Disk Drives • Form factor: 3.5" HDD or 2.5" SSD SAS drives
• Interface: 12Gb/6Gb SAS; 6Gb SATA
• 10W per drive
Drive Partitioning / Split Bus Zoning • Drive array can be zoned in four pre-defined zoning configurations supported by the I/O modules
• Additional zoning configurations can be developed upon request
Host Expansion Interfaces • Two SAS JBOD I/O modules, each with 4-wide, 24 Gb/s mini SAS HD expansion ports
Failure Notifications • SCSI enclosure services (SES-3.0) over in-band interface and via system status and FRU LEDs
Monitoring & Reporting • Monitors temperature, power, cooling (including fan speed control), disk drives, and I/O modules
• In-band reporting of all FRU and chassis serial numbers, part numbers and revisions
AC Power • Input voltage 200-240V AC
• Input frequency: 50-60 Hz
• Power supplies: 2 (n+1)
• Input current: 9.4 amps max @ 200V AC per power supply
• Maximum system continuous DC output power rating: 1600W
Hot-Swappable Components • Two JBOD IO modules
• Two AC to DC power modules
- Two 1600W power supplies
- Two +5V regulators per enclosure/system provide hard drive power
• Two independent AC power inputs
• Up to 102 drives in the main bay
Firmware • SCSI enclosure services (SES) 3.0-based firmware
Operating Environment • Temperature: 5° to 35°C
• Relative humidity: 20% to 80% (non-condensing)
• Altitude: -200 ft to 10,000 ft
• Shock: 3.5G at 11ms, 1/2 sine wave pulse
• Vibration: 0.10G at 5 Hz to 500 Hz
• Acoustics (declared sound power): 92 dB with I/O modules; at idle/active operation tested to ISO 7779
Non-Operating Environment • Temperature: 5° to 45°C
• Relative humidity: 10% to 90% (non-condensing)
• Altitude: -200 ft to 10,000 ft
• Shock: 7G at 11ms, 1/2 sine wave pulse
• Vibration: 3G at 5 Hz to 500 Hz